Chinese Journal of Ultrasonography ; (12): 590-599, 2023.
Article in Chinese | WPRIM | ID: wpr-992861

ABSTRACT

Objective:To investigate the effect of instantaneous flow rate on the consistency of diagnostic accuracy of severe degenerative mitral regurgitation (DMR) using proximal isovelocity surface area (PISA).Methods:From June 2019 to June 2021, 75 patients with DMR who underwent echocardiography in Department of Echocardiography of Zhongshan Hospital, Fudan University were prospectively enrolled. The instantaneous flow rate of DMR during the systolic phase was calculated using M-mode PISA(PISA M-mode), and a time-integrated curve was plotted. Regurgitant volume (RVol) and effective regurgitant orifice area (EROA) were calculated by traditional PISA (PISA max), pair PISA (PISA pair), and PISA M-mode, respectively. RVol acquired from cardiac magnetic resonance (CMR) volumetric method in 22 patients of the enrolled patients. The correlation and consistency of RVol acquired between the three PISA methods and CMR were compared. Agreement of diagnostic accuracy of severe mitral regurgitation (sMR) acquired between the three PISA methods and multi-parameter algorithm by American Society of Echocardiography (ASE) was analyzed using Cohen′s Kappa analysis. Results:The curve of instantaneous flow rate of DMR showed unimodal pattern with the peak at mid-late systolic phase. The correlation of RVol acquired between PISA methods and CMR was moderate for PISA max and PISA pair ( r=0.77, 0.80, both P<0.001), whereas PISA M-mode presented strong correlation with CMR ( r=0.87, P<0.001). RVol acquired from PISA max was larger than that of CMR[(69.1±37.1) ml vs (49.0±29.0)ml, P=0.002]. Both PISA max and PISA pair were shown moderate agreement of diagnostic accuracy of sMR with ASE multi-parameters algorithm (RVol: κ=0.496, 0.525, both P<0.001; EROA: κ=0.570, 0.578, both P<0.001), while PISA M-mode presented strong agreement (RVol: κ=0.867 and EROA: κ=0.802, both P<0.001). Conclusions:Based on the unimodal pattern of instantaneous flow rate in patients with DMR, PISA max may significantly overestimate RVol, exposing a significant proportion of patients with DMR to unnecessary MR surgery. PISA M-mode presents better correlation and consistency with CMR on the quantification of RVol compared with PISA max and PISA pair, and may improve the diagnostic accuracy of quantification of sMR using PISA.

2.
Chinese Journal of Ultrasonography ; (12): 449-454, 2023.
Article in Chinese | WPRIM | ID: wpr-992851

ABSTRACT

Transcatheter tricuspid valve intervention is the new frontier of interventional cardiology. The LuX-Valve is a radial force-independent orthotopic tricuspid valve replacement device developed in China. The LuX-Valve Plus transcatheter tricuspid valve replacement (TTVR) system is changed from the trans-atrial to the transjugular approach, which further reduces trauma and pulmonary complications compared with the first generation LuX-Valve. The first-in-human study has been completed at Zhongshan Hospital, Fudan University and an exploratory multicentre clinical study is underway. Echocardiography plays an important role in pre-TTVR screening, intraoperative guidance and postoperative evaluation and follow-up, especially two-dimensional transoesophageal echocardiography (2D-TEE) and three-dimensional transoesophageal echocardiography (3D-TEE). However, there is a lack of appropriate intraoperative guidance and assessment protocols. In this study, we briefly described the protocols and imaging considerations for intraoperative 2D-TEE and 3D-TEE to ensure the successful implantation of TTVR.

3.
Chinese Journal of Laboratory Medicine ; (12): 1240-1244, 2022.
Article in Chinese | WPRIM | ID: wpr-958650

ABSTRACT

Objective:To explore the indication of bacterial artificial chromosome-on-beads identification/separation technology in prenatal diagnosis and its application value.Methods:The inclusion criteria were as follows: age ≥35 years, high risk/critical risk of serological prenatal screening, high risk of non-invasive gene testing (NIPT), abnormal ultrasonic indexes or adverse pregnancy history. From April 2016 to December 2020, 3579 amniotic fluid samples collected from pregnant women with singletons were detected by bacterial artificial chromosome-on-beads identification/separation technique (BoBs) and G-banding karyotype analysis simultaneously. The aneuploid abnormality/microdeletion/microdeletion samples detected by karyotype analysis or BoBs were verified by fluorescence in situ hybridization (FISH)/SNP array as needed.Results:(1) The percentage of samples with indications of advanced maternal age, high risk of NIPT and high risk of serological screening was 89.44%(3 201/3 579), the detection rate of aneuploidy was 96.19%(202/210), and the detection rate of microdeletion/microduplication was 87.5%(28/32),the total abnormal detection rate was 95.04% (230/242). The samples with abnormal ultrasonic indexes, adverse pregnancy history and critical risk indications of serological screening in the second trimester accounted for 10.66%, and the abnormality of aneuploidy and micro-duplication/micro-deletion was 4.96%. (2) 198 common chromosome aneuploidies (13/18/21/X/Y) were detected by BoBs, and 12 cases with chimeras ≥20% were found, which were consistent with karyotype results. Two copies of 21-trisomy, three copies of X/Y, seven copies of 2, 7, 8, 9, 10, 20, mar karyotype chimerism, eight copies of arm inversion and five copies of translocation outside the detection range of probes were detected by karyotype analysis. The sensitivity, specificity and false negative rate of BoBs detection for five aneuploidies were 94.6%(210/222), 100% and 5.4%(12/222), respectively. BoBs and karyotype analysis detected 32 and 9 cases of microdeletions/microduplications respectively. Compared with single karyotype analysis, the combined application of G-banding karyotype analysis and BoBs can detect an additional 9.4% (23/244)positive samples.Conclusion:The samples with elder age, high risk of NIPT, and high risk of serological screening are more suitable as indications for the application of BoBs in prenatal diagnosis.

4.
Chinese Journal of Ultrasonography ; (12): 626-630, 2022.
Article in Chinese | WPRIM | ID: wpr-956636

ABSTRACT

Tricuspid regurgitation (TR) interventions are under rapid development. The K-Clip? system is the first domestic transcatheter tricuspid annuloplasty system with unique clamping procedure to achieve annular reduction.Intraoperative echocardiographic monitoring procedures for transcatheter tricuspid annuloplasty have not been reported yet in China. Thus, this review aimed to propose the standard two-dimensional and three-dimensional transesophageal echocardiographic workplanes and procedures to guide and monitor the implantation of K-Clip system based on our experience in Zhongshan Hospital, Fudan University to provide a reference point for the intraoperative echocardiographic monitoring of future transcatheter tricuspid annuloplasty devices in China.

5.
Chinese Journal of Ultrasonography ; (12): 758-763, 2021.
Article in Chinese | WPRIM | ID: wpr-910117

ABSTRACT

Objective:To investigate the relationship between Watchman occluder and structure of mitral valve apparatus in patients with nonvalvular atrial fibrillation after left atrial appendage closure(LAAC) by transesophageal echocardiography.Methods:From January 2018 to December 2020, 29 patients [20 male, 9 female, (69.55±10.06)years old] with nonvalvular atrial fibrillation underwent LAAC in Zhongshan Hospital (implanted Watchman occluder), and all patients underwent pre-operative and follow-up two and three dimensional transesophageal echocardiography(2DTEE, 3DTEE) at 60 days after the operation. The quantitative parameters of mitral valve apparatus were obtained by offline analysis using the MVA module in QLab 13.0 (Philips Healthcare, Andover, MA), the differences between pre-operation and post-operation were compared, and the relationship between occluder compression ratio and mitral valve parameters with significant changes after operation was analyzed.Results:①The values of AL-PM diameter(AL-PM), 3D annulus circumference(3DAC), 2D annulus area(2DAA), 3D annulus area(3DAA), tenting volume(TnV), tenting area(TnA) and commissural diameter(CD) decreased significantly compared with pre-operative values(all P<0.05), while the annulus sphericity index(SPI) increased significantly ( P<0.05). ②In the quantitative mitral value parameters with significant pre- and post-operation changes, TnV was correlated with the occluder compression ratio ( r=0.403, P=0.030), but AL-PM, SPI, 3DAC, 2DAA, 3DAA, TnA, CD were not correlated with it(all P>0.05). Conclusions:3DTEE can accurately evaluate the effect of Watchman occluder on the morphology of mitral valve device. Implanting Watchman occluder in left atrial appendage can make three-dimensional mitral valve apparatus flat and decrease annulus left-right diameter and annulus area; the pre-operative TnV, the more susceptible to the occluder implantation, and TnV is correlated with the compression ratio.

6.
Chinese Journal of Ultrasonography ; (12): 382-386, 2019.
Article in Chinese | WPRIM | ID: wpr-754814

ABSTRACT

Objective To evaluate the role of transthoracic echocardiography ( T T E ) and transesophageal echocardiography( T EE) in the process of transapical mitral valve repair using a novel edge‐to‐edge device( ValveClamp) and this device′s efficacy and safety in a preliminary clinical trial . Methods Six patients with moderate to severe or severe degenerative mitral regurgitation ( DM R) confirmed by T T E and T EE were enrolled . T T E was performed pre and post procedure as well as 30 days post procedures . Related cardiac structure and hemodynamic parameters ,including mitral regurgitation area ( MRA‐max ) , vena contracta width ( VCW ) ,mitral valve effective orifice area ( M VEOA ) ,left ventricular end diastolic diameter ( LVEDD ) , left ventricular end systolic diameter ( LVESD ) , left ventricular ejection fraction ( LVEF) ,max and mean mitral valve pressure gradient ( M VPG‐max and M VPG‐mean) were recorded and evaluated in a central core laboratory . Results All the procedures were successfully performed .M RA‐max , VCW and M VEOA decreased significantly post procedures ( all P < 0 .000 ) , and they remained no significant changes within 30 days post procedures ( all P > 0 .05 ) . M eanwhile ,M VPG‐max and M VPG‐mean slightly increased ( all P <0 .01 ) and left atrial anterior‐posterior dimension attenuated 30 days post procedures( P <0 .05) ,but all M VPG‐mean were lower than 5 mm Hg ( 1 mm Hg=0 .133 kPa) . T here were no significant changes in other hemodynamic parameters ( all P > 0 .05) . Conclusions T ransapical mitral valve repair using ValveClamp can be performed safely and a significant reduction in mitral regurgitation can be achieved in patients with DM R . T EE and T T E facilitate the patient selection for ValveClamp procedures as well as perioperative navigation and assessment .

7.
Chinese Journal of Ultrasonography ; (12): 277-281, 2018.
Article in Chinese | WPRIM | ID: wpr-707667

ABSTRACT

Objective To discuss the clinical value of real-time myocardial contrast echocardiography ( RT-MCE) on quantitative assessing myocardial perfusion in patients with coronary slow flow ( CSF ) . Methods CSF group contained 14 patients with CSF and 15 cases with normal coronary angiography ( CAG) were involved as control group . The 2D echocardiography and RT-MCE images from standard 3 apical views ( 4-chamber ,2-chamber ,and long-axis) were acquired . All images were digitally stored on hard disks for offline analysis by QLab software . The RT-MCE parameters included myocardial blood volume ( A) , myocardial blood veloity ( β) ,myocardial blood flow ( MBF) were used to predict the impairment of myocardial perfusion in the two groups . Results In CSF group ,the value of β and MBF in abnormal segments were significantly lower than those in normal segments ( P < 0 .001) . There was no significant difference of A between the abnormal segments and the normal segments in CSF group ( P > 0 .05 ) . Compared to the control group ,the value of β and MBF were significantly lower in abnormal segments of CSF group( P < 0 .001) . Comparing the normal segments of two groups ,there was no significant difference in the values of A ,β and MBF ( P > 0 .05) . ROC curve analysis showed the AUC of β was the biggest ( AUC = 0 .867 , P < 0 .001 ) , and when the cut-off value was 1 .34 , the impairment of myocardial microcirculation was best predicted ( sensitivity ,79 .6% ;specificity ,77 .4% ) . Conclusions The myocardial perfusion in patients with CSF can be appraised by RT-MCE quantitatively . The value of β can identify the early impairment of myocardial microcirculation perfusion in patients with CSF and has the promising prospect of clinical diagnosis .

8.
Chinese Journal of Ultrasonography ; (12): 563-568, 2017.
Article in Chinese | WPRIM | ID: wpr-615198

ABSTRACT

Objective To investigate the alternation of right ventricular volume and systolic function in patients with severe pulmonary regurgitation under percutaneous pulmonary valve implantation(PPVI) by real-time three-dimensional echocardiography(RT-3DE).Methods Ten patients with severe pulmonary regurgitation were enrolled.The 2D echocardiography images and real-time 3D full volume images on apical four-chamber view on a Philips IE33 system were acquired before PPVI and at 3 days,1 month,3months and 6 months after PPVI.Right ventricular end diastolic volume (EDV),end systolic volume(ESV),stroke volume (SV),ejection fraction(EF),fractional area change(FAC),tricuspid annular plane systolic excursion (TAPSE),right ventricular longitudinal strain-free wall(RVLSf) and right ventricular longitudinal strainseptum(RVLSs) were analysed using off-line TomTec software,the differences among the five groups were compared,and correlation analysis was made between the CMR and RT-3DE measurements.Results The level of pulmonary regurgitation had decreased or disappeared after PPVI.Compared with the preoperation,EDV,ESV at 3 days,1 month,3months and 6 months after operation had decreased significantly.EF,FAC,TAPSE,RVLS had increased significantly(all P <0.05).There were close correlation in EDV,ESV,EF between RT-3DE and CMR(pre-operation r =0.811,0.817,0.807,post-operation r =0.735,0.834,0.800,all P <0.055).Conclusions RV volume notably decreases while RV systolic function remarkably improves.The RT-3DE is a helpful technology in the evaluation of right ventricular volume and systolic function in patients after PPVI.

9.
Chinese Journal of Ultrasonography ; (12): 277-281, 2017.
Article in Chinese | WPRIM | ID: wpr-609694

ABSTRACT

Objective To evaluate the left ventricle systolic function in patients with aortic stenosis (AS) underwent transcatheter aortic valve implantation(TAVI) by speckle tracking imaging and to observe the indicators in bicuspid aortic valves(BAV) and tricuspid aortic valves(TAV) groups.Methods Twenty nine patients with AS were enrolled,all of them underwent TAVI successfully.The regular echocardiography and 3D full-volume images were acquired on before and 3 days,1 month after TAVI.Longitudinal strain,circumferential strain,and three-dimensional left ventricle ejection fraction(3D-LVEF) were analyzed using Qlab software.Results Compared with the baseline,aortic valve blood flow velocity (AV),maximum aortic valve pressure gradient (AVPG-max),mean aortic valve pressure gradient (AVPG-mean),aortic valve area(AVA) after TAVI were improved significantly.Global longitudinal strain(GLS) had a improvement on 3 days after TAVI(all P <0.001),and further increased during 1 month after TAVI (all P <0.001).Global circumferential strain(GCS) were increased during 1 month after TAVI(all P < 0.001).The 3D-LVEF after 1 month were improved significantly(all P <0.001).The BAV patients and TAV patients had similar changes in all of indicators observed.Conclusions The left ventricle systolic function has early improvement after TAVI,and further recovery during follow-up.The BAV patients can obtain a benefit from TAVI equally to the TAV patients.

10.
Chinese Journal of Medical Imaging Technology ; (12): 490-493, 2017.
Article in Chinese | WPRIM | ID: wpr-608695

ABSTRACT

The prevalence of patent foramen ovale (PFO) in adults is up to 20%-25%.PFO is associated with cryptogenic stroke in young patients,transient ischemic attack and several other diseases.Echocardiography plays a critically important role in screening of PFO,guidance during percutaneous intervention and follow up.The diagnosis of PFO by echocardiography were reviewed in this article.

11.
Chinese Journal of Ultrasonography ; (12): 1021-1025, 2016.
Article in Chinese | WPRIM | ID: wpr-508523

ABSTRACT

Objective To investigate the difference between three-dimensional transesophageal echocardiography ( 3DTEE) and CT in measuring the size of aortic ring and the height of coronary ostium . Methods Fifteen patients were recruited and were treated with the transcatheter aortic valve implantation ( TAVI) . Routine transthoracic echocardiography ,two-dimensional echocardiography ( 2DTEE) ,3DTEE and CT examinations were taken preoperatively . Results The minimal diameter ,maximum diameter , perimeter ,area of the aortic ring measured by 3DTTE showed a close correlation and a strong consistency with those measured by CT [ r = 0 .88 , P < 0 .0001 ,ICC = 0 .928 (0 .788 - 0 .976) ; r = 0 .81 , P = 0 .0003 , ICC = 0 .890 ( 0 .673 - 0 .963) , r = 0 .85 , P = 0 .0001 ,ICC = 0 .914 ( 0 .744 - 0 .971) ; r = 0 .88 , P <0 .0001 ,ICC = 0 .932 (0 .799 - 0 .977) ] .The ostium height of the left and right coronary arteries measured by 3DTEE also showed a close correlation and a strong consistency with those measured by MDCT [ r =0 .87 , P < 0 .0001 ,ICC = 0 .923 ( 0 .777 - 0 .975) ; r = 0 .82 , P < 0 .0002 ,ICC = 0 .897 ( 0 .693 - 0 .965) ] . Besides ,inter-observer and intra-observer reproducibility for 3DTEE measurement data were very good . Conclusions 3DTEE has a high repeatability in evaluating minimal diameter , maximum diameter , perimeter ,area of the aortic ring and the height of coronary ostium ,which also shows good correlation with those measured by CT .

12.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 887-892, 2016.
Article in Chinese | WPRIM | ID: wpr-641168

ABSTRACT

Objective To investigate the value of two-dimensional and three-dimensional transesophageal echocardiography (3DTEE) in transcatheter aortic valve implantation (TAVI). Methods Eleven patients with severe aortic stenosis and one patient with moderate to severe prosthetic valve regurgitation underwent TAVI in Zhongshan Hospital of Fudan University from May 2010 to December 2015. All patients received two-dimensional and three-dimensional transthoracic and transesophageal echocardiographic examination before surgery, during and after surgery.Results Procedural success was achieved in eleven patients, but one patient died in pericardial tamponade and aortic dissection three days after TAVI. The maximum and minimum diameter of aortic annule, the area of aortic annule and aortic valve were measured by multidetector computed tomography (MDCT) and 3DTEE before surgery. All parameters had strong correlations between MDCT and 3DTEE (r=0.98,P<0.01 for maximum diameter;r=0.97,P<0.01 for minimum diameter;r=0.97,P<0.01 for the area of aortic annule;r=0.99, P<0.01 for the area of aortic valve). There were good correlations for the area of aortic valve among MDCT, 3DTEE and equation of continuity (allr=0.99,P<0.01).ConclusionTwo-dimensional and three dimensional transesophageal echocardiography can quantify the size of aortic annular and comprehensively evaluate the anatomical structure of aorta rapidly and accurately, which can be used in guiding TAVI and monitoring its complications in real time.

13.
Chinese Journal of Ultrasonography ; (12): 378-380,381, 2015.
Article in Chinese | WPRIM | ID: wpr-601366

ABSTRACT

Objective To quantitatively evaluate left ventricular layer-specific strain using speckle tracking imaging,and their relationship with age and gender in nornal subj ects.Methods GE Vivid E9 equipment with EchoPAC BT1 2 workstation were used.One hundred and nineteen healthy subj ects were enrolled in this study.Results Left ventricular global longitudinal and circumferential strain was highest in the endocardium and lowest in the epicardium.Longitudinal and circumferential 3-layer strain was highest in the apex and lowest in the base.Age and gender had little influence on the left ventricular layer-specific strain.Conclusions Speckle tracking imaging can quantitatively assess left ventricular layer-specific strain, providing another useful modality for evaluating cardiac function.

14.
Chinese Journal of Ultrasonography ; (12): 553-557, 2014.
Article in Chinese | WPRIM | ID: wpr-455583

ABSTRACT

Objective To evaluate the global and segmental (inflow,body and outflow) systolic functions of right ventricle in end-stage renal failure (ESRF) patients by real-time three-dimensional echocardiography(RT-3DE) and four-dimensional right ventricle quantitative analysis (4D-RVQ) and to reveal the long-term impact of renal insufficiency on right ventricular systolic function.Methods RT-3DE was performed in 48 ESRF patients and 26 healthy individuals (control group).Images were acquired and analysed off-line in TomTec 4D-RVQ station.The parameters of RV global and segmental systolic functions,including RV global and segmental end-diastolic volume (EDV),end-systolic volume(ESV),stroke volume(SV),ejection fraction(EF),the time to minimum systolic volume(T-msv) were obtained.All the variables were standardized by body surface area (BSA) or heart rate (HR).Results ① In the ESRF group,EDV,SV and EF of body compartment were significantly higher than those of the controls[EDV:(8.5±3.4)ml/m2 vs (6.4± 1.7)ml/m2,P =0.002;SV:(4.5 ± 1.7)ml/m2 vs (2.7±0.9)ml/m2,P =0.0037;EF:(45.4 ± 11.5)% vs (41.1 ± 7.1)%,P =0.0489],and so were EDV,SV of inflow compartment [EDV:(19.6± 1.0)ml/m2 vs (16.5±0.9)ml/m2,P =0.0438;SV:(12.3±4.6)ml/m2 vs (10.1±3.2) ml/m2,P =0.0433].②Compared with the control group,the global and segmental T-msv were all delayed obviously in the ESRF group (P < 0.001).③The percentage of SV of body compartment accounting for the global SV significantly increased in the ESRF group [(19.5 ± 7.3)% vs (15.5 ± 5.5)%,P =0.0222],while that of outflow compartment reduced significantly [(20.3 ± 7.0)% vs (26.8 ± 8.2)%,P =0.0005].Conclusions The global and segmental systolic functions of right ventricle were impaired in ESRF patients,especially in the body compartment.The RT-3DE and 4D-RVQ are helpful technologies in the evaluation and follow-up of right ventricular systolic function in patients with renal failure.

15.
Chinese Journal of Ultrasonography ; (12): 6-11, 2013.
Article in Chinese | WPRIM | ID: wpr-432064

ABSTRACT

Objective To evaluate right ventricular (RV) global and regional volume and systolic function in patients with secondum atrial septal defect (ASD) using real-time three-dimensional echocardiography (RT3DE),and to explore the relationship between parameters derived from RT3DE and parameters measured by conventional echocardiography.Methods RT3DE images were acquired from 22 patients with secundum ASD and 22 normal controls for evaluation and analysis to obtain RV global and regional end-diastolic volume (EDV),end systolic volume (ESV),systolic volume (SV) and ejection fraction (EF) in three compartments (inflow,body and outflow).RV dyssynehrony parameters were calculated as the standard deviation (SD) and maximum difference (dif) of time to minimum systolic volume (Tmsv) and Tmsv corrected by heart rate (Tmsv%) in three RV compartments.Conventional echocardiographic parameters including pulmonary artery systolic pressure (PASP),pulmonary vascular resistance (PVRe) and maximum diameter of ASD (ASD-D) were calculated and recorded.Results RV global and regional EDV,ESV and SV were larger (all P <0.001) and EF was lower (all P <0.05) in the ASD group than in the controls.RV regional volume and systolic function were changed to various degrees in different compartment in the patients group.There were no significant differences in Tmsv,Tmsv% and RV dyssynchrony parameters between the two groups.In patients with ASD,RV global and regional EDV,ESV and SV in the inflow compartment were positively correlated with ASD-D and PASP (r =0.463-0.704,all P < 0.05) ; RV global EF was negatively correlated with PVRe (r =-0.477,P < 0.05).Conclusions In patients with ASD,RV global and regional volume was enlarged and systolic function was impaired with distinct characteristics; RV global volume and regional volume in the inflow compartment were positively correlated with RV pre-load while RV global EF was negatively correlated with RV afterload.

16.
Chinese Journal of Ultrasonography ; (12): 704-707, 2012.
Article in Chinese | WPRIM | ID: wpr-427661

ABSTRACT

Objective To investigate the impact of myocardial contrast echocardiography (MCE) on evaluating the myocardial perfusion in beagles with ischemic cardiomyopathy and cardiac resynchronization therapy (CRT),and to estimate the myocardial perfusion by myocardial blood flow (MBF) value.Methods Twelve adult beagles were randomly divided into two groups (CRT group and non-CRT group).Each beagle underwent a ligature in the first diagonal branch and a pacemaker was implanted.The pacing was started in CRT group,but was not started in non-CRT group.MCE and speckle tracking imaging were performed to evaluate the MBF value and circumferential strain (Cir1 2SD),radial strain (R12SD) and longitudinal strain (L12SD) of 12 segments of left ventricle at baseline,before CRT,and 4 weeks after CRT.Results There was no significant difference of LVEF,LVEDV,LVESV,Cir12SD,and R12SD between two groups at baseline or before CRT( P >0.05).After 4 weeks of CRT,LVEF,LVEDV,LVESV,Cir1 2SD,and R 12SD in two groups were ( 58.8 ± 8.2 ) % vs (39.5 ± 8.7 ) %,(28.2 ± 2.9) ml vs (34.2 ± 2.5 ) ml,( 13.9± 2.6 ) ml vs (21.5± 4.7)ml,(29.1 ± 6.6)ms vs (46.5 ± 10.1)ms and (36.1 ± 10.7)ms vs (67.6± 11.2)ms( P <0.05 ).A,β,and MBF value between two groups were ( 13.6 ± 2.2 )dB vs ( 14.9 ± 3.0)dB,(5.1±1.1 )s- 1 vs (4.8 ± 2.1 )s- 1,(67.6 ± 12.1)dB/s vs (72.8 ± 8.6)dB/s( P >0.05) at baseline and were (7.4 ± 1.2)dB vs (7.3±2.7)dB,(3.9±0.9)s-1 vs (2.9±0.9)s-1,(23.4±4.2)dB/s vs (22.2±4.1)dB/s (P>0.05)before CRT.After 4 weeks of CRT,A,β,and MBF value in CRT group were higher than those in non-CRT group (12.1 ± 1.8)dB vs (9.5 ± 1.7)dB,(4.7 ± 0.3)s-1 vs (3.1 ± 0.8)s-1,(47.2 ± 8.6)dB/s vs (29.5 ±4.2)dB/s,all P <0.05).Conclusions In beagles with ischemic cardiomyopathy,CRT can not only improve cardiac synchrony,but also increase myocardial perfusion.

17.
Chinese Journal of Ultrasonography ; (12): 747-751, 2011.
Article in Chinese | WPRIM | ID: wpr-421751

ABSTRACT

Objective To evaluate right ventricular (RV) global and regional systolic function using real-time three-dimensional echocardiography (RT-3DE) in patients with pulmonary hypertension (PH).Methods Thirty patients with PH and 27 controls were studied.RT-3DE images were acquired on a Philipa iE33 system with an X3-1 probe,then analyzed with a new software(TomTec) to determine RV global and regional (inflow, body, outflow) end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF).The difference of RT-3DE parameters between the two groups,as well as the correlation between RT-3DE and routine echoeardiography parameters was analyzed.Results In patients with PH ,RV global and regional EDV and ESV were significantly higher than those in normal controls (all P <0.05); RV global and regional EF were significantly lower than those in normal controls (all P <0.05).In the PH group, RV inflow EDV,SV and EF were higher than that of RV body and outflow part (P < 0.05) ;RV global EF was lower than that of RV inflow part and higher than that of RV body and outflow part.In the PH group, RV global and inflow EF correlated with pulmonary artery systolic pressure negatively (r = - 0.611, P <0.001 and r = - 0.576, P = 0.001 ,respectively) ,and with the ratio of peak velocity of tricuspid regurgitation over outflow time-velocity integral negatively (r = -0.772, P = 0.002and r = -0.721, P <0.001, respectively)Conclusions RV global and regional volume was enlarged and systolic function was impaired in patients with pulmonary hypertension.RV global and regional systolic function was changed in liner relationship with RV after-load.

18.
Chinese Journal of Ultrasonography ; (12): 108-111, 2011.
Article in Chinese | WPRIM | ID: wpr-384346

ABSTRACT

Objective To investigate the value of real-time three-dimensional echocardiography(RT-3DE) timing-excursion parametric index and 17 segment time-volume curves index in patients with leftventricular noncompaction(LVNC). Methods Ten patients with LVNC (proven by MRI) ,twenty subjects with normal LV function were examined by Philips iE33 with X3-1 probe. Results Parameter index (including Tmsv 16-SD,Tmsv 12-SD,Tmsv 6-SD,Tmsv 16-Dif,Tmsv 12-Dif,Tmsv 6-Dif,Tmsv 16-SD%,Tmsv 12-SD%, Tmsv 6-SD%, Tmsv 16-Dif%, Tmsv 12-Dif%, Tmsv 6-Dif%) of 17 segment time to minimal systolic volume was significantly higher in patients with LVNC than that in subjects with normal LV function( all P<0.05). Average and minimum value of excursion was significantly lower in patients with LVNC than that in subjects with normal LV function ( P<0.05). Conclusions RT-3DE with timeexcursion parameters and 17 segment of time- volume curve parameters can rapidly and accurately evaluate left ventricular systolic synchrony in patients with LVNC.